+ 94 76 150 7607 info@snailanka.com

50,000 L/H R.O. Water Purification System

Product Details

Design basis and treated water standard:

1. Design Basis

1.1 Water source: had better provide us the water analysis report to confirm

1.2 Produced water’s application: Pure drinking water
1.3 The capacity of produced water: 50,000L /H

1.4 Designed recovery: 50-65%.

1.5 Rejection rate: ≥ 97%

1.6 Operation Mode: Automatic run by PLC control

1.7 Voltage: 3 phases, 380V, 50Hz; Power: 85KW

1.8 Requirement of source water inlet:

1) PH: 6.5-7.5

2) SDI(pollution index) ≤4

3) Residual chlorine: ≤0.1mg/L

4) Salt content: ≤250ppm

5) Ion: ≤0.1ppm

6) NTU: ≤2

7) Temperature: 25℃

 

Main Components List:

 

Basic Configuration Item Description Qty(set) Remark
Pretreatment part Feed pump CNP CDL85-20 4 380V/50Hz; 15kw

Lift: 41meter

Flow rate: 85M3/H

Material: SS304

Rotate speed: 2900r/min

Mechanical filter Φ2000×3400 2 SS304

Thickness: 4.0MM

Active Carbon filter Φ2000×3400 2 SS304

Thickness: 4.0MM

Softener Φ1800×3000 2 SS304 filter tank, 3000L PE Salt Tank, 3kw regeneration pump
Micron filter 40″×50 core 2 SS304
RO Part Pressure pump CNP CDL42-80-2 4 380V/50Hz;  30KW

Lift: 142meter

Flow Rate: 42M3/H

Material: SS304

Rotate speed: 2900r/min

RO membrane BW30-400 50 Imported American DOW FILMTEC Membrane
Membrane vessel 8040″x 5m 10 FRP
Flow Rate Meter for water inlet 12-90T/H 2 Organic glass
Flow Rate Meter for concentrated water outlet 12-40T/H 2 Organic glass
Automatic cleaning butterfly valve DN65 2 SS304
Pressure gage 17 SS304
Pneumatic Butterfly Valve DN80 30 SS304
Manual Butterfly Valve DN80 13 SS304
DN65 10 SS304
Check valve DN80 4 SS304
High pressure sluice valve DN65 4 SS304
DN80 4 SS304
RO Membrane Washing System 1 SS304
Frame and pipeline of RO System 1 SS304 Frame, SS304 Pipeline
Electric Control System Conductivity Meter CCT-3320 4
Flow transmitter 2 GF
Control box With Mitsubishi PLC + transducer 1 SS304