50,000 L/H R.O. Water Purification System
Product Details
Design basis and treated water standard:
1. Design Basis
1.1 Water source: had better provide us the water analysis report to confirm
1.2 Produced water’s application: Pure drinking water
1.3 The capacity of produced water: 50,000L /H
1.4 Designed recovery: 50-65%.
1.5 Rejection rate: ≥ 97%
1.6 Operation Mode: Automatic run by PLC control
1.7 Voltage: 3 phases, 380V, 50Hz; Power: 85KW
1.8 Requirement of source water inlet:
1) PH: 6.5-7.5
2) SDI(pollution index) ≤4
3) Residual chlorine: ≤0.1mg/L
4) Salt content: ≤250ppm
5) Ion: ≤0.1ppm
6) NTU: ≤2
7) Temperature: 25℃
Main Components List:
| Basic Configuration | Item | Description | Qty(set) | Remark |
| Pretreatment part | Feed pump | CNP CDL85-20 | 4 | 380V/50Hz; 15kw
Lift: 41meter Flow rate: 85M3/H Material: SS304 Rotate speed: 2900r/min |
| Mechanical filter | Φ2000×3400 | 2 | SS304
Thickness: 4.0MM |
|
| Active Carbon filter | Φ2000×3400 | 2 | SS304
Thickness: 4.0MM |
|
| Softener | Φ1800×3000 | 2 | SS304 filter tank, 3000L PE Salt Tank, 3kw regeneration pump | |
| Micron filter | 40″×50 core | 2 | SS304 | |
| RO Part | Pressure pump | CNP CDL42-80-2 | 4 | 380V/50Hz; 30KW
Lift: 142meter Flow Rate: 42M3/H Material: SS304 Rotate speed: 2900r/min |
| RO membrane | BW30-400 | 50 | Imported American DOW FILMTEC Membrane | |
| Membrane vessel | 8040″x 5m | 10 | FRP | |
| Flow Rate Meter for water inlet | 12-90T/H | 2 | Organic glass | |
| Flow Rate Meter for concentrated water outlet | 12-40T/H | 2 | Organic glass | |
| Automatic cleaning butterfly valve | DN65 | 2 | SS304 | |
| Pressure gage | 17 | SS304 | ||
| Pneumatic Butterfly Valve | DN80 | 30 | SS304 | |
| Manual Butterfly Valve | DN80 | 13 | SS304 | |
| DN65 | 10 | SS304 | ||
| Check valve | DN80 | 4 | SS304 | |
| High pressure sluice valve | DN65 | 4 | SS304 | |
| DN80 | 4 | SS304 | ||
| RO Membrane Washing System | 1 | SS304 | ||
| Frame and pipeline of RO System | 1 | SS304 Frame, SS304 Pipeline | ||
| Electric Control System | Conductivity Meter | CCT-3320 | 4 | |
| Flow transmitter | 2 | GF | ||
| Control box | With Mitsubishi PLC + transducer | 1 | SS304 |